Pipe Plugs for Rent

United Rentals carries an extensive catalog of pipe plug rentals. Our pipe test plugs are designed for pressure testing, isolation and flow control, pipe sealing, and other similar applications.

For our full list of pipe plug equipment for rent, view the items below. For more information, visit our resource section.

Cat Class Code
500-1666

30 ft. High-Pressure Read Back Hose

  • 30 ft. hose length
  • 1/4 in. hose diameter
  • Standard quick disconnect fittings
  • 11 lbs.
  • Uses: Ideal for performing high-pressure air testing in pipelines
Cat Class Code
500-1688

20 ft. Fill Kit & Retrieval Rope with Gauge

  • 20 ft. hose length
  • 3/8 in. hose inside diameter
  • Swivel NPT fitting
  • 8 lbs.
  • Uses: Ideal for plug inflation and retrieval
Cat Class Code
500-4200

12-24 in. Blocking Pipe Plug

  • Fits 12-24 in. pipes
  • 30-45 PSI required inflation pressure
  • 13-15 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow, air tests and vacuum testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4220

15-32 in. Blocking Pipe Plug

  • Fits 15-32 in. pipes
  • 25 PSI required inflation pressure
  • 11-12 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow, air tests and vacuum testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4250

18-40 in. Pipe Plug, 4 in. Bypass

  • Fits 18-40 in. pipes
  • 25 PSI required inflation pressure
  • 4 in. bypass
  • Features a relief valve and sleeve
  • Uses: Ideal for bypassing flow, gravity bypassing and testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4290

20-40 in. Pipe Plug, 6 in. Bypass

  • Fits 20-40 in. pipes
  • 20-25 PSI required inflation pressure
  • 6 in. bypass
  • Features a relief valve and sleeve
  • Uses: Ideal for flow diversion and manhole rehabilitation
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4300

24-48 in. Blocking Pipe Plug

  • Fits 24-48 in. pipes
  • 25 PSI required inflation pressure
  • 10-11 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow, air tests and vacuum testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4340

24-60 in. Pipe Plug, 4 in. Bypass

  • Fits 24-60 in. pipes
  • 25 PSI required inflation pressure
  • 4 in. bypass
  • Features a relief valve and sleeve
  • Uses: Ideal for bypassing flow, gravity bypassing and testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4345

24-60 in. Pipe Plug, 6 in. Bypass

  • Fits 24-60 in. pipes
  • 25 PSI required inflation pressure
  • 6 in. bypass
  • Features a relief valve and sleeve
  • Uses: Ideal for bypassing flow and gravity bypassing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4350

24-60 in. Blocking Pipe Plug

  • Fits 24-60 in. pipes
  • 25 PSI required inflation pressure
  • 6-9 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow, air tests and vacuum testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4390

48-72 in. Blocking Pipe Plug

  • Fits 48-72 in. pipes
  • 10-12 PSI required inflation pressure
  • 6-7 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow in large-diameter pipes
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4400

48-72 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 48-72 in. pipes
  • 10-12 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow and controlled expansion testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4430

54-96 in. Blocking Pipe Plug

  • Fits 54-96 in. pipes
  • 10-12 PSI required inflation pressure
  • 6-7 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow in the largest pipelines
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-4440

54-96 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 54-96 in. pipes
  • 10-12 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow and controlled expansion testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-7260

8 in. High-Pressure Pipe Plug, 2 in. Bypass

  • Fits 8 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. bypass
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7261

10 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 10 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7262

12 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 12 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7263

24 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 24 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7264

30 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 30 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7265

36 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 36 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7266

42 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 42 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7267

48 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 48 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7268

54 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 54 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7269

60 in. High-Pressure Pipe Plug, 2 in. and 3/4 in. Bypasses

  • Fits 60 in. pipes
  • 225 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. and 3/4 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7470

4-8 in. High-Pressure Pipe Plug, 3/8 in. Bypass

  • Fits 4-8 in. pipes
  • 200 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 3/8 in. bypass
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7471

8-12 in. High-Pressure Pipe Plug, 1 in. and 1/2 in. Bypasses

  • Fits 8-12 in. pipes
  • 200 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 1 in. and 1/2 in. bypasses
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7474

12-16 in. High-Pressure Pipe Plug, 2 in. Bypass

  • Fits 12-16 in. pipes
  • 200 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. bypass
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7480

16-20 in. High-Pressure Pipe Plug, 2 in. Bypass

  • Fits 16-20 in. pipes
  • 200 PSI required inflation pressure
  • 150 PSI maximum back pressure
  • 2 in. bypass
  • Uses: Ideal for testing high-pressure pipeline systems
Cat Class Code
500-7910

6-12 in. Blocking Pipe Plug

  • Fits 6-12 in. pipes
  • 35-45 PSI required inflation pressure
  • 11-15 PSI maximum back pressure
  • No bypass flow-through
  • Uses: Ideal for blocking flow, air tests and vacuum testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8260

12-24 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 12-24 in. pipes
  • 30-45 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8280

15-32 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 15-32 in. pipes
  • 25 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8300

24-48 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 24-48 in. pipes
  • 25 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8321

6-10 in. Pipe Plug, 4 in. Bypass

  • Fits 6-10 in. pipes
  • 35-40 PSI required inflation pressure
  • 10 PSI maximum back pressure
  • 4 in. bypass
  • Uses: Ideal for gravity bypassing or bypass pumping
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8335

8-12 in. Pipe Plug, 4 in. Bypass

  • Fits 8-12 in. pipes
  • 35-45 PSI required inflation pressure
  • 10-15 PSI maximum back pressure
  • 4 in. bypass
  • Uses: Ideal for gravity bypassing or bypass pumping
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8365

15-32 in. Pipe Plug, 6 in. Bypass

  • Fits 15-32 in. pipes
  • 20-25 PSI required inflation pressure
  • 6 in. bypass
  • Features a relief valve and sleeve
  • Uses: Ideal for flow diversion and manhole rehabilitation
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8370

15-32 in. Pipe Plug, 4 in. Bypass

  • Fits 15-32 in. pipes
  • 25 PSI required inflation pressure
  • 4 in. bypass
  • Features a relief valve and sleeve
  • Uses: Ideal for bypassing flow, gravity bypassing and testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8662

18-40 in. Blocking Pipe Plug

  • Fits 18-40 in. pipes
  • 25 PSI required inflation pressure
  • 10-11 PSI maximum back pressure
  • Features a relief valve and sleeve
  • Uses: Ideal for blocking flow, air tests and vacuum testing
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8778

50 ft. Low-Pressure Air Testing Triple Hose

  • 50 ft. hose length
  • Features a 3/8 or 1/4 in. diameter red hose, a 3/4 or 1/2 in. diameter blue hose, and a 3/8 or 1/4 in. diameter yellow hose
  • Locking quick disconnect fittings
  • 26 lbs.
  • Uses: Ideal for performing low-pressure air testing in pipelines
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8806

4-6 in. Tester Pipe Plug, 1/4 in. Bypass

  • Fits 4-6 in. pipes
  • 45 PSI required inflation pressure
  • 13-17 PSI maximum back pressure
  • 1/4 in. bypass
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8807

6-12 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 6-12 in. pipes
  • 30-45 PSI required inflation pressure
  • 11-15 PSI maximum back pressure
  • 3/4 in. and 1/4 in. bypass options
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-8817

18-40 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 18-40 in. pipes
  • 25 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-9019

25 ft. Low-Pressure Air Testing Triple Hose

  • 25 ft. hose length
  • Features a 3/8 or 1/4 in. diameter red hose, a 3/4 or 1/2 in. diameter blue hose, and a 3/8 or 1/4 in. diameter yellow hose
  • Locking quick disconnect fittings
  • 20 lbs.
  • Uses: Ideal for performing low-pressure air testing in pipelines
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
500-9024

Low-Pressure Air Testing Control Panel

  • Includes a test pressure gauge, inflation gauge and air regulator
  • Hose connection diameters are 1/4 in., 3/4 in. and 3/8 in.
  • Connects to air compressors with crow's foot or standard quick disconnect fittings
  • 20 lbs.
  • Uses: Ideal for performing low-pressure air testing in pipelines
Cat Class Code
500-9599

24-60 in. Tester Pipe Plug, 3/4 in. or 1/4 in. Bypass

  • Fits 24-60 in. pipes
  • 25 PSI required inflation pressure
  • 3/4 in. and 1/4 in. bypass options
  • Features a relief valve and sleeve
  • Uses: Ideal for air testing, vacuum testing and blocking flow
  • Specifications may vary within the ranges provided above depending on the model you receive
Cat Class Code
545-9817

1,000 PSI Manual Hydrostatic Test Pump

  • Manual hydrostatic test pump
  • Pump pressure up to 1,000 PSI
  • Glycerin-filled gauge reads up to 2,000 PSI
  • 10 ft. discharge hose
  • Uses: Ideal for testing the structural integrity of pipes and vessels
Resources

FAQs About Pipe Plugs

At United Rentals, we offer low and high-pressure testing plugs from high-quality brands like Cherne, Oatey, Lansas, Plug Technologies and more. We offer rental periods of days, weeks and months to suit your project's needs. Rent pipe test plugs in diameters ranging from 6 to 96 inches with several options like bypass plugs and inflatable pipe plugs. Our selection also includes fill kits and retrieval ropes to make inflation and retrieval as simple as possible.

Learn more about pipe plugs in our FAQ section below.

FAQs
What size pipe plug do I need for my application?

Pipe sizes are usually standardized, meaning you can match the plug’s stated size range to your pipe’s internal diameter (ID). Pipe plugs have a minimum and maximum size range, so ensure the plug you choose is compatible with the pipe size you are working with. An undersized plug won’t seal off the pipe, while an oversized plug can be a safety hazard. If you cannot identify the pipe’s ID, measuring the interior diameter can work as well.

How do I measure a pipe’s internal diameter for accurate plug testing?

Use digital calipers or a pipe gauge to measure the pipe’s ID by measuring the distance between the inside walls, ensuring you exclude the pipe wall thickness. Measure at several angles to account for ovality and make sure the pipe is clean of obstructions.

How to calculate the required back pressure rating for a pipe plug?

Calculating the back pressure rating for a pipe plug involves finding the maximum force exerted by the pipe's internal pressure, based on the pipe's radius, maximum pressure (PSI) and pressure head.